INTELLIGENT CLOUD PLATFORM
Real-time monitoring of all slots
Remote diagnostics and control
Automatic alarm notifications
Usage data analytics and reporting
ADVANCED POWER MANAGEMENT
Precision current/voltage monitoring
Per-slot energy consumption tracking
Dynamic load balancing
SAFETY PROTECTIONS
Auto-stop at full charge (≥95% efficiency)
Over-current/voltage protection
Fire-resistant enclosure (IP54 rated)
VIDEO VERIFICATION SYSTEM
Tamper-proof operation recording
Transaction authenticity confirmation
Security incident documentation
ENVIRONMENTAL ADAPTABILITY
Built-in heater (0-40°C activation)
Forced air cooling system
Coastal operation ready (salt-spray resistant)
Parameter | Specification |
---|---|
Models | CX-03CC (3-slot) / CX-12HA (12-slot) |
Dimensions (W×D×H) | CX-03CC: 1000×600×1500mm CX-12HA: 1700×1470×500mm |
Input Voltage | AC 220V ±20% |
Input Frequency | 50Hz ±5Hz |
Max. Total Power | 6000W |
Max. Power per Slot | 750W |
Charging Current | 0-15A (adjustable per slot) |
Charging Voltage | 40-90V (wide range) |
Battery Compatibility | 45-72V Lithium Batteries |
Cooling Method | Forced Air Cooling |
Protection Rating | IP54 |
Heating System | Integrated Heater |
Heating Temp. Range | 0°C to 40°C |
Communication | Ethernet + 4G |
Operating Temp. | -20°C to 50°C |
Operating Humidity | 5% to 95% RH (non-condensing) |
Max. Altitude | ≤2000m |
Atmospheric Pressure | 80-110 kPa |
Factor | Requirement |
---|---|
Air Quality | Free from acidic/alkaline/corrosive gases |
Humidity Control | Maintain specified RH range |
Safety Measures | Lightning protection required |
Fire Prevention | Install fire suppression systems |
Storage | Use dry bubble wrap for components |